Skalar Robotics Training Evaluation
Name
First Name
Last Name
Email
example@example.com
Date
-
Month
-
Day
Year
Date
Back
Next
Put in the right order the sequence:
Software Structure
A computer can have multiple versions of Plugins and Tools
True
False
A computer can have multiple Applications
Yes
No
Making a backup the following files and folders can be deleted:
Analysis folder
SkalarPacks folder
Unhandled Dump
Logs
Xml Backup Files
Back
Next
Planner & Users
The planner can be used for:
One day type of Analysis (pH)
Two days type analysis (BOD)
All type of analysis
Customer can add new users:
True
False
Back
Next
Analysis Status
Put the BOD analysis on the right sequence:
Back
Next
Sample Analysis Table
Remeasure will:
Change a row status remeasuring
Change an analysis status to remeasuring
Change a row status to Selected
Back
Next
Tables
Select the Shared Type Tables:
Probes
DeviceConfiguration
Settings
Sample Analysis
RoboticsSettings
What is the name of the table on the previous picture?
Probes
StabilityLoop
StabilitySettings
MeasurementSettings
Looking at the picture, what is the fastest time to get a stable pH measurement?
5 seconds
6 seconds
4 seconds
Back
Next
Heading
Back
Next
Positioning
You can use the function HomeAndGetPositions() on and SP100:
Yes
No
On an Old BOD application, the position values for the Waste positions are located in:
Settings Table
RoboticsSettings Table
Positions Table
Other
On Skalar Robotics, a position with a x Value of 1200, means:
12 mm
120 mm
1,2 cm
Back
Next
BOD Deccaper
A dual decapper can decap one bottle only:
True
False
The positions for the Gripper are in:
Settings Table
RoboticsSettings Table
GripperSettings Table
RoboticsSettings and GripperSettings Table
Back
Next
SSPL
Put in the right order the sequence:
On SP100 the SSPL commands are used:
True
False
Select the SSPL command to turn the a rinse pump on connected to the "pump 2" connector of the SP2000 board:
PUMP 2 ON
PUMP (2) ON
PUMP (2,100)
PUMP (2 ON)
Select the SSPL command that will turn On a stirrer connected to the "Stirrer 1" connector on an SP100 robot:
Stirrer (1,0)
STIRRER (2,45)
STIRRER (1,100)
STIRRER (1) ON
Back
Next
Import/ Export/ Print
Which filter will only show the samples with pH on an export layout?
Status1 = Selected
pH_YN = true
pH > 0
It is possible to change the sequence of the Columns on a print layout
True
False
Import Layouts are saved on:
Application folder
Core Folder
SVN
Back
Next
Application BOD
For a BOD5 analysis, a blank is always needed:
True
False
Put the BOD 5 sequence in order:
Back
Next
BOD Calibration
Put the BOD calibration in order:
Back
Next
Application SOIL
On a pH/EC measurement:
pH is measured before EC
EC is measure before pH
Measurement is done according the customer request
Back
Next
Backup
Put the backup procedure sequence in order:
Submit
Should be Empty: