Line Readiness Inspection
Email
*
example@example.com
Inspector Name
*
Please Select
Rubel Mia
Ammar Faris
Abdul Qayyum
Omar Ariff
DateTime
*
Production Line
*
Please Select
L1
L2
L3
L4
L5
L6
L15
L16
L17
L18
L19
L20
L21
L22
Type of Product
*
Robotic Arm Station Parameter
*
Actual Reading
Air Jet Pressure Reading
(Std: 3 to 5 Bar)
Robotic Arm Station Condition
*
Good
Bad
Cuff Brush Condition
Cuff Brush Cleanliness
Air Jet Pressure Condition
Air Jet Pressure Cleanliness
Air Jet Pressure Positioning
Gripper Arm Condition
Gripper Knife Condition
Track Holder Condition
Track Holder Cleanliness
Machine Cover Condition
Auto Stacking Condition
*
Good
Bad
Green Conveyor Condition
Green Conveyor Cleanliness
Sensor Condition
Semi Roller Condition
Semi Roller Cleanliness
Track Holder Condition
Track Holder Cleanliness
Pulling Brush Condition
Pulling Brush Cleanliness
Pulling Brush Sensor Condition
Acid Tank 1 Parameter
*
Actual Reading
Acid Temperature
(Std: 40 to 70°C)
Acid Tank 1 Level
*
Low
Standard
High
Acid Tank 1 Level
Acid Tank 1 Condition
*
Good
Bad
Track Holder Condition
Track Holder Cleanliness
Acid Cleanliness
Alkaline Tank Parameter
*
Actual Reading
Alkaline Tank 1 Temperature
(Std: 40 to 70°C)
Alkaline Tank 2 Temperature
(Std: 40 to 70°C)
Alkaline Tank Level
*
Low
Standard
High
Alkaline Tank 1 Level
Alkaline Tank 2 Level
Alkaline Tank Condition
*
Good
Bad
Alkaline Tank 1: Track Holder Condition
Alkaline Tank 1: Track Holder Cleanliness
Alkaline Tank 1: Alkaline Cleanliness
Alkaline Tank 2: Track Holder Condition
Alkaline Tank 2: Track Holder Cleanliness
Alkaline Tank 2: Alkaline Cleanliness
Circular Washing Brush Tank
*
Good
Bad
Brush Condition
Brush Cleanliness
Former Wetting
Brush Chain Condition
Tank Cleanliness
Water Rinsing Tank Parameter
*
Actual Reading
Water Rinsing Tank 1 Temperature
(Std: 50 to 60°C)
Water Rinsing Tank 2 Temperature
(Std: 50 to 60°C)
Water Rinsing Tank Level
*
Low
Standard
High
Water Rinsing Tank 1 Level
Water Rinsing Tank 2 Level
Water Rinsing Tank Condition
*
Good
Bad
Water Rinsing Tank 1: Track Holder Condition
Water Rinsing Tank 1: Track Holder Cleanliness
Water Rinsing Tank 1: Water Cleanliness
Water Rinsing Tank 2: Track Holder Condition
Water Rinsing Tank 2: Track Holder Cleanliness
Water Rinsing Tank 2: Water Cleanliness
Coagulant Tank Parameter
*
Actual Reading
Coagulant Tank Temperature
Coagulant Tank Level
*
Low
Standard
High
Coagulant Tank Level
Coagulant Tank Condition
*
Good
Bad
Stirrer
(Good: ON, Bad: OFF)
Filter Availability
(Good: Available, Bad: Unavailable)
Filter Condition
Track Holder Condition
Track Holder Cleanliness
Coagulant Cleanliness
Coagulant Oven Parameter
*
Actual Reading
Coagulant Oven Temperature
Coagulant Oven Condition
*
Good
Bad
Coagulant Oven Cleanliness
Latex Tank Parameter
*
Actual Reading
Latex Tank 1 Temperature
(Std: 34 to 40°C)
Latex Tank 2 Temperature
(Std: 34 to 40°C)
Latex Tank Level
*
Low
Standard
High
Latex Tank 1 Level
Latex Tank 2 Level
Latex Tank Condition
*
Good
Bad
Latex Tank 1 Stirrer
(Good: ON, Bad: OFF)
Latex Tank 1 Filter Availability
(Good: Available, Bad: Unavailable)
Latex Tank 1 Filter Condition
Latex Tank 1 Track Holder Condition
Latex Tank 1 Track Holder Cleanliness
Latex Tank 1 Cleanliness
Latex Tank 2 Stirrer
(Good: ON, Bad: OFF)
Latex Tank 2 Filter Availability
(Good: Available, Bad: Unavailable)
Latex Tank 2 Filter Condition
Latex Tank 2 Track Holder Condition
Latex Tank 2 Track Holder Cleanliness
Latex Tank 2 Cleanliness
Pre Leaching Tank (PLT) Parameter
*
Actual Reading
Pre Leaching Tank 1 Temperature (°C)
Pre Leaching Tank 1 TDS (ppm)
Pre Leaching Tank 2 Temperature (°C)
Pre Leaching Tank 2 TDS (ppm)
Pre Leaching Tank 3 Temperature (°C)
Pre Leaching Tank 3 TDS (ppm)
Pre Leaching Tank Level
*
Low
Standard
High
Pre Leaching Tank 1 Level
Pre Leaching Tank 2 Level
Pre Leaching Tank 3 Level
Pre Leaching Tank Condition
*
Good
Bad
Pre Leaching Tank 1 Gutter Condition
Pre Leaching Tank 2 Gutter Condition
Pre Leaching Tank 3 Gutter Condition
Beading Station Condition
*
Good
Bad
Carpet / Brush Condition
Carpet / Brush Cleanliness
Track Holder Condition
Track Holder Cleanliness
Main Oven Parameter
*
Actual Reading
Main Oven Zone 1 Temperature
(Std: 105 to 145°C)
Main Oven Zone 2 Temperature
(Std: 105 to 145°C)
Main Oven Zone 3 Temperature
(Std: 105 to 145°C)
Main Oven Zone 4 Temperature
(Std: 105 to 145°C)
Main Oven Zone 5 Temperature
(Std: 105 to 145°C)
Main Oven Zone 6 Temperature
(Std: 105 to 145°C)
Main Oven Condition
*
Good
Bad
Main Oven Zone 1 Cleanliness
Main Oven Zone 2 Cleanliness
Main Oven Zone 3 Cleanliness
Main Oven Zone 4 Cleanliness
Main Oven Zone 5 Cleanliness
Main Oven Zone 6 Cleanliness
Cooling Tank Parameter
*
Actual Reading
Cooling Tank 1 Temperature
(Std: 50 to 70°C)
Cooling Tank 2 Temperature
(Std: 50 to 70°C)
Chlorine Tank Level
*
Low
Standard
High
Chlorine Tank Level
Chlorine Tank Condition
*
Good
Bad
Chlorine Tank Cleanliness
Final Drying Oven Parameter
*
Actual Reading
Final Drying Oven Temperature
(Std: 100 to 150°C)
*For White &
Translucent Products Only
Final Drying Oven Condition
*
Good
Bad
Final Drying Oven Cleanliness
Former Holder
*
Actual Quantity
Missing Former Washer
(Std: Must be less than 25 pcs out of 500 pcs)
Loosen Pin
(Std: Must be less than 25 pcs out of 500 pcs)
Former Knocking
(Std: Must be less than 25 pcs out of 500 pcs)
Poor Cleanliness
(Std: Must be less than 25 pcs out of 500 pcs)
Disposition
*
Please Select
PASS
MINOR FAILURE
CRITICAL FAILURE
Acknowledgement by (Production Supervisor/Officer/Chemist/Engineer)
*
Clear
Submit
Should be Empty: