Exterior Checklist...
Check saddles to insure for 12" extention beyond brick walls
Punch Needed
Check brick & siding elevations for proper exterior trim
Punch Needed
Check porch beams for height & width and ceilings for 2x nailers installed.
Punch Needed
Check roof lines on hip ends & gables for straight
Punch Needed
Check roof eyebrows for completion and roof sheathing is set if brick passes through.
Punch Needed
Check any bay options for correct roof pitch, soffit overhang, and wall height.
Punch Needed
Check that all cantilevers and fireplaces are sheathed & Tyvek wrapped underneath.
Punch Needed
Check Tyvek for compete installation and no holes.
Punch Needed
Check lot for cleanliness (no scrap). All remaining material stacked neatly.
Punch Needed
Other Punch Needed
Garage Checklist...
Check for sill plate straps or anchor bolts 6' O.C max and no more than 12" from plant ends.
Punch Needed
Check that temp stair built and fastened.
Punch Needed
Check that any attic access(s) are framed per plan.
Punch Needed
Check for garage back jambs.
Punch Needed
Check garage door head opening (84" O.F.F.)
Punch Needed
Check garage portal walls for proper nailing pattern & connector straps per plan.
Punch Needed
Check that steel beams are lag bolted (3/8"x3-1/2" MIN) to PSL columns with full bearing.
Punch Needed
Check that steel beams and columns are padded for drywall.
Punch Needed
Check for bowed/crowned studs that need repaired/replaced
Punch Needed
***Full height and depth studs required on all bearing walls. Non bearing walls can be cut and scabbed with 2x4
Check that walls over 10' are fire blocked.
Punch Needed
**All fire blocking must be 1-1/2" thick**
Check that lumber rack built on exterior wall.
Punch Needed
Other Punch Needed
Basement Checklist...
Check for joist bridging or center span blocking.
Punch Needed
Check for all needed bearing blocks in floor container.
Punch Needed
Check that flat 2x10 blocking installed per plan at top of joists for kitchen counter point loads
Punch Needed
Check 1st Floor joist layout (O.C. spacing, dbl joists, nailing pattern, etc.).
Punch Needed
Check walls under stair landing for code.
Punch Needed
Check for bowed/crowned studs (mark all to be repaired)
Punch Needed
***Full height and depth studs required on all bearing walls. Non bearing walls can be cut and scabbed with 2x4
Check for plumb and squared walls.
Punch Needed
Check for 8' O.C. 2x4 vertical fire stop against concrete walls and 2x6 horizontal fire block at top of foundation.
Punch Needed
**Any fire blocking touching concrete to be treated**
Other Punch Needed
Stairs Checklist...
Check for minimum 36" landing from stair tread nosing
Punch Needed
Check that required nailers are installed for drywall.
Punch Needed
Check that stairs are set to proper height for floor covering selections.
Punch Needed
Check to insure treads are level.
Punch Needed
Other Punch Needed
First Floor Checklist...
Check that subfloor sheathing is nailed properly and spaced (6"/12" & 1/8" gap at all edge and end joints)
Punch Needed
Check for bowed/crowned studs (mark all to be repaired)
Punch Needed
**Full height & depth studs required all bearing walls. Interior non bearing walls cut and scab 2x4**
Check door & window rough openings for correct size and location. No cap nails to be within 2" of (or) inside R.O.
Punch Needed
Check for plumb and squared walls.
Punch Needed
Check that any field framed half or knee walls are framed and braced to joist.
Punch Needed
Check kitchen cabinet blocking for 2x6 @ 34-1/2", 54-1/2", & 97"
Punch Needed
Check fireplace & raised hearth dimensions. FP at raised hearth to be held 1" higher than hearth. Stone on FP to be sheathed with OSB.
Punch Needed
Check for all required lath catch at corners & ceilings.
Punch Needed
Check any "dead space" for fire stopping (1-1/2" thickness required.)
Punch Needed
Check 2nd floor joist layout (O.C. spacing, dbl joists, nailing pattern, etc.).
Punch Needed
**Any 4-ply beams must be bolted 2' O.C. staggered w/ 1/2 inch bolts**
Other Punch Needed
Second Floor Checklist...
Check for plumb and squared walls..
Punch Needed
Check that any field framed half or knee walls are framed and braced to joist.
Punch Needed
Check for bowed/crowned studs (mark all to be repaired)
Punch Needed
Check any "dead space" for fire stopping (1-1/2" thickness required.)
Punch Needed
**preferred material is (2) layers of 3/4 inch scrap OSB or 2x blocing**
Check door & window rough openings for correct size and location. No cap nails to be within 2" of (or) inside R.O.
Punch Needed
Check tub nailer's at all tub corners (full height studs required).
Punch Needed
Check for correct drop ceilings over showers and closets.
Punch Needed
Check that shower curbs are framed.
Punch Needed
Check for all required lath catch at corners & ceilings.
Punch Needed
Check joists to allow for plumbing traps 10” off wall, & toilets 12” to 13” off wall from center plumbing.
Punch Needed
Other Punch Needed
Roof Checklist...
Check all trusses for H-2.5's and connector hangers are installed with proper nails.
Punch Needed
Check all girder trusses are nailed or bolted per truss engineering specs.
Punch Needed
Check that all gable end wall trusses are strong-backed mid way & braced properly.
Punch Needed
**The strong-back 2x4 L brace needs to be mid way between top & bottom cord.
Check that required permanent bracing has been installed per truss engineering.
Punch Needed
Check dormers for no vertical 2x4’s showing in window.
Punch Needed
Check that roof sheathing is held back 1-1/2" each side of gable peak for ventilation.
Punch Needed
Check OSB is cut out of dormer bottoms for ventilation.
Punch Needed
Check that holes for "roof box vents" are cut out for ventilation.
Punch Needed
Check any "trey" or "hip trey" ceilings for straightness.
Punch Needed
**Use 2x material or 3/4 inch OSB for perimeter material. No 7/16 inch OSB**
Check flat ceilings for any excessive high or low truss bottom cords.
Punch Needed
Check to insure roof peak sheathing rippers are 12" & wider per code.
Punch Needed
Check to insure that OSB is installed in vaulted areas.
Punch Needed
Other Punch Needed
Safety Checklist....
Check that all window & door openings are safety blocked off at 18" & 42"
Punch Needed
Check that all safety rail and boots installed properly. 2-rail on stairs, 3 rail on landings, (only 1- rail required on basement stairs).
Punch Needed
Check that any balcony walls have 2x4 "safety toe rail" installed.
Punch Needed
Check for "tie-off" anchors installed on rear roof.
Punch Needed